Shopping Cart

Mishin coils BIOLIS 03 MAX set

Mishin coils BIOLIS 03 MAX set
Product Code :03 max
Availability :In Stock
  • $690.00

Free Shipping

Shipping time 12-14 days.

Ask a question

SET BIOLIS 03 MAX          6 coils included           English manuals           110/220V


                                               

Kit «BIOLIS-03 MAX» today is the maximum set in the entire line of manufactured equipment “BIOLIS”. This kit includes all possible magnetic, electromagnetic, electric coils, both classic developed by Nikola Tesla and modified new items. By purchasing this kit, you certainly get the entire possible range of effects of torsion fields. And also do it with the maximum convenience for yourself and your loved ones.

Non-contact inductive method is based on scientific conclusions of famous scientists of

the last centenary. Nikola Tesla, Georges Lakhovsky and Raymond Rife discovered a positive

influence of resonant electromagnetic fields (waves) on disturbed potentials of a cell membrane.

Nevertheless, this phenomenon had not been used in practical medicine for a long time because

of absence of technical possibilities. Since 2016 the system of resonant therapy has developed

into non-contact inductive physiotherapy and obtained wide-spread occurrence.

Inductive therapy is carried out with the aid of special electromagnetic inductors (“coil”,

“loop”, “belt”, etc.) which are applied on a head or projection areas of a patient.

Inductive therapy is a base for switch-on and more optimal application of mechanisms of

self-regulation of a human organism. Due to capability of an organism to remember obtained

data, effect from sessions of the given therapy is preserved for a long time.


Characteristics:

The device is a small-sized device made in a shock-resistant case. Inside the case there is an electronic microprocessor control unit of the apparatus, a generator of electromagnetic oscillations with a flexible cable of emitter coils attached to it. LED indicators of output power (current) are located on the left side of the front (front) part of the device.


                            


                                                   


MAIN SPECIFICATIONS:


Model................................................. ................................................. ............................... BIOLIS-03
Output frequency: ............................................... ................................................. ................50-800kHz
Capacitive output power: ............................................... .................................................. 1 to 15 W
Inductive output power: ............................................... ............................................... 1 to 15 W
Increment power: .............................................. ................................................. ................. 10 W
Mode:................................................ ................................................. .... SWD (Continuous Therapy)
PSWD:................................................... ................................................. ................... (pulse therapy)*
Pulse Width: ............................................... ................................................. .... 100 to 400 µs*
Pulse frequency: ............................................... ................................................. ....... 50 to 800 Hz*
Time of the therapy session: .............................................. ....... 300 minutes (in increments of 1 minute)
Capacitive area of ​​large coil: .............................................. ....................................... 250 cm2
Large coil inductive area: .............................................. ................................... 250 cm 2
Capacitive area of ​​the middle coil: ............................................... ......................................... 95 cm2
Inductive area of ​​the middle coil: ............................................... ....................................... 95cm 2
AC adapter input frequency : .............................................. ......................100 / 240~ 50/60Hz
Power consumed from the network, no more than, VA: .............................................. ...................................... 24
Time of continuous operation, no more than, min: .............................................. ......................................... 300
Electrical class: ............................................... ................................................. ................. Class I
Circuit breakers:................................................ ................................................. ...... 0.5A 250~ (20AG)
Degree of electrical protection: ............................................... ................................................. .Type BF
Apparatus dimensions, mm ............................................... ................................................. ........ 180X130X50


Set included:

Physiotherapy apparatus BIOLIS-03

Big reel

Medium coil

Coil "TOR"

Magnetic field coil

Electric field coil

flexible coil

Field indicator

Network adapter

Owner's manual and passport in English, French and Spanish



Write a review

Note: HTML is not translated!
    Bad           Good