High frequency unit ( violet ray Korona ) with 18 argon electrode in set. 



Although primarily for various skin and scalp conditions, such as Acne, Wrinkles, Dandruff, Gray Hair and Baldness the Violet Ray is helpful for many other disorders (including some serious conditions). It appears to also work by Balancing and Energizing the Nervous System and moves the "Chi".

It has been in use since the late 1800's (see the links to some of the original manuals, below).

The "Violet Ray High frequency Device" is a miniature version of the "Body Enhancer" device. It is so much more affordable and you can take it with you anywhere for instant healing. This "Violet Ray" Tool is a Lymphatic drainage device that can detox heavy metals and chemicals from the body.

In addition it replaces any missing harmonics and magnetic field elements to the body energy field, Unsticks blood cells while improving circulation and introducing ozone to add oxygen to the blood. Can be used for localized areas.

I offer you a well made portable device which is used for therapy as well as improvement in sports medicine, and in cosmetology.

This device is known in Russia under the name D'Arsonval. In the USA its name is Violet Ray. During the procedure, an impulse of high voltage alternating microcurrent effects the skin surface without hurting bio structures of tissues.

Procedures are carried out every day or every second day, in total 10 to 15 times.

The procedure provides purification of skin, curing abscesses and injuries, and activates the self protecting features of the skin. Thanks to all the above-mentioned characteristics the procedure is successfully used for solving a lot of problems in both cosmetology and medical practice.




Indications

  • Skin diseases (eczema, herpes, blackheads, neurodermitis, furuncle, burns, frostbite, bruises, bad injures, etc.)
  • Hair (falling out, gray, poor quality, etc.)
  • Infections (nasal, ear and other special electrodes available)
  • Air passage diseases (trachea infection, bronchitis, asthma, etc.)
  • Sinus diseases (allergies, head cold, etc.)
  • Diseases of joints, muscles, tendons
  • Artery and vein diseases (endarteritis, varicose vein, thrombophlebitis)
  • Neurosis, problems with sleeping, osteohondrosis, etc.

The effect of the D'Arsonval procedure is caused by activation of micro circulation, broadening the arteries and capillaries of skin and subcutaneous cellulose. At the same time activity of the venous system improves and swollen tissues tend to decrease.

The procedure provides removing of blueish spots which usually remains after blackheads. It is also used for correcting the function of oil glands. Due to the effect of D'Arsonval current anesthetic and anti itching effects are supplied. In addition it provides activation of biochemical exchanging processes in skin and subcutaneous oil cellulose and increases the nourishment of tissues supplying them with oxygen.

The glass electrodes are filled with neon gas and have an orange color when the power is applied. The therapeutic influence of violet and orange electrodes is very similar.

The unit is made in the Ukraine, and comes in the original packaging, new in the case, with 17 glass electrodes

The unit consists of:

  • Violet Ray wand
  • Transformer with amplitude regulator on the bottom, connected to the Violet Ray wand by a cord.

Comes with 18 electrodes          

      

 

 

Mushroom, slingshot,  leaf

Specifications

  • At the output devise provides an electric signal in the form of pulse train with the following parameters:
    • pulse repetitionf requensy of 120+-10 Hz;
    • carrier frequency of 110+-50 kHz;
    • the amplitude value (8 kV, maximum) to the maximal one (from 16 to 25 kV)
  • The apparatus operates on mains of alternating current witha frequency of (60+-0.5) Hz and a voltage of 220 V
  • The root-men-square value of the current consumed by the apparatus on the mains does not exceed 1 A.
  • The settling time of the operating mode from the moment of swithing-on does not exceed 30 s.
  • Energizing of the device is accompanied by light indication.
  • The device provides continuous operation during 8 hours, maximum, witha subsequent interval of 30 min, minimum, in the repetitive short-term mode: operating time 20 min, pause 10 min.
  • Mass of the device together with the electrode is 0,85 kg.
  • Device overall dimensions:
    • oscillator body - 155*69*65 mm
    • transformer body - 170*50*50 mm

European standard electric plug

Voltage requirements:

Supply Voltage: 220 volt

In the USA, Japan, and UK an adapter will be needed.

A NOTE for US customers: you will need to convert US voltage from 110 V AC to 220-240 V AC (you can choose an adaptor for example HERE).